Guides

True position calculator

A position tolerance tells you how far a hole or pin's center can sit from its true position, the exact spot set by the basic dimensions. When the callout uses a material condition modifier (MMC or LMC), the tolerance zone is not fixed. It grows when the feature is away from its material condition. That growth is the bonus tolerance.

This guide gives you the arithmetic, so you can check any position callout by hand before you trust a drawing.

The three numbers you need

For each feature, you need:

  1. The feature's size tolerance, for example Ø8.00 +0.10 / 0.
  2. The position callout tolerance, for example ⌀0.25.
  3. The actual mating size of the feature, from its actual mating envelope: the largest perfect cylinder that fits inside a hole, or the smallest one that contains a pin. It is not a two-point measurement.

From the size limits, find the two material sizes:

The formulas

Bonus is how far the feature is from its material condition, in the direction that gives more room.

FeatureAt MMCAt LMC
HoleBonus = actual − MMC sizeBonus = LMC size − actual
PinBonus = MMC size − actualBonus = actual − LMC size

The actual size for the LMC column is the actual minimum material size: the largest a hole is, or the smallest a pin is.

Total zone = position tolerance + bonus.

A feature at its tightest material condition gets no bonus. A feature at its loosest gets the full size tolerance as bonus. Note which way the hole goes: the largest hole is at LMC and gets the full bonus.

Two limits to remember:

Position error is a diameter zone, so the error is twice the radial offset:

Position error = 2 × √(dx² + dy²)

where dx and dy are the feature's center offsets from true position in the two axes. The feature passes when its position error is no more than the total zone.

Worked example 1: a clearance hole

Callout: position ⌀0.25 Ⓜ on a hole Ø8.00 +0.10 / 0.

CaseActual mating sizeBonusTotal zone
At MMC (smallest hole)8.000.000.25
Measured8.060.060.31
At LMC (largest hole)8.100.100.35

Take the measured hole at 8.06. Its center is off true position by dx = 0.10 and dy = 0.10.

If the same hole's center were 0.20 off in one axis, the error would be 2 × 0.20 = 0.40, which fails the 0.31 zone. Doubling the radial offset is the step most people miss.

Worked example 2: a locating pin

Callout: position ⌀0.10 Ⓜ on a pin Ø6.00 +0 / −0.05.

MMC is 6.00 (largest pin). LMC is 5.95 (smallest pin).

CaseActual mating sizeBonusTotal zone
At MMC (largest pin)6.000.000.10
Measured5.970.030.13
At LMC (smallest pin)5.950.050.15

A smaller pin gives more room, because it can sit off-center in the hole without fouling the mating part.

A sphere's centre can be located by a spherical zone, written SØ in the frame. The zone is a ball around the true position, so the deviation uses all three offsets: 2 × √(x² + y² + z²). A hole or a pin has a cylindrical zone along its axis, and only the two offsets across the axis count.

Try it

Enter your own limits, callout and measured values, or load either worked example.

More calculators in the Toolbox

Before you release the drawing

Run these checks on any position callout:

  1. Is the modifier right for the mating condition? Use MMC when the feature is a clearance fit and the assembly is checked at its extremes. Use LMC where minimum wall or edge distance is the concern. Use RFS for press fits and features whose size does not change how they mate.
  2. Does the datum reference frame match the function? A position callout is only as good as the datums it refers to. See how to choose datums.
  3. Is the zone big enough for the process? Compare the total zone at LMC with what the machine and the inspection can hold.
  4. Does the size tolerance still make sense? A tight size tolerance with a loose position callout wastes the bonus. A loose size tolerance with a tight position callout gives a large bonus that the inspection may not be able to check.

Common mistakes

  1. Adding bonus to a hole at its smallest size, or a pin at its largest. Those are MMC, and they get no bonus. The largest hole is LMC and gets the full bonus.
  2. Using the nominal size instead of the actual mating size. Bonus is always measured from the actual mating size, not from the drawing nominal.
  3. Forgetting that RFS has no bonus. A frame with no modifier does not grow.
  4. Expecting bonus to shift a datum on a flat surface. A flat surface has no material size, so there is no bonus. A material condition on a datum (MMB or LMB) allows datum shift, which is a different thing from bonus.

Questions

Is bonus tolerance the same as the total zone?

No. Bonus is the extra amount. The total zone is the stated position tolerance plus the bonus.

What if the hole is smaller than MMC?

Then it is out of size and is rejected before position is checked. Bonus only applies to features that are inside their size limits.

Why use MMC instead of RFS?

MMC gives the shop more room when holes are made at the loose end of their size range, as long as the fit still works. RFS is stricter, so use it when the mating fit cannot take any extra variation.