Toolbox

Bolted joint calculator

You have a preloaded bolt clamping metal parts and an external load pulling the joint apart, and you want to know how much of that load the bolt sees, how much clamp is left, and the margins against the joint opening and the bolt reaching its proof load. It loads with a worked example filled in. The tool gives no typical values: the moduli, the preload and the load are yours to type.

More calculators in the Toolbox

Section through a bolted joint: head, two clamped plates, nut, the grip length l, the shank and thread lengths ld and lt, and the 30° pressure cones
A bolt and nut through two plates, with the pressure cones from the 1.5 d bearing faces.

Bolt stiffness

The bolt is a spring made of two parts in series: the unthreaded shank of length ld, with area Ad = π d² / 4, and the threaded length lt = l − ld, with the tensile stress area At. Its stiffness is kb = Ad At Eb / (Ad lt + At ld), where Eb is the bolt's modulus. Threaded the whole grip, kb = At Eb / l. The bolt is taken as the grip length only. The head and nut add flexibility, so the real C is lower than shown, by more on a short grip. The bolt load is then a little lower than shown, and the joint opens at a slightly lower load.

Member stiffness and the pressure cone

The clamped parts are squeezed in a cone that widens at 30° from the bearing face, which is taken as 1.5 d across at both ends. The tool treats the members as two equal frusta back to back, each of thickness t = l / 2, with dw = 1.5 d. One frustum has stiffness k = π Em d tan 30° / ln[ ((2 t tan 30° + dw − d)(dw + d)) / ((2 t tan 30° + dw + d)(dw − d)) ], and the two together, in series, give km = k / 2. This assumes the clamped parts extend well beyond the bolt on every side, so the pressure cone isn't cut off by an edge or a neighbouring hole. The pressure-cone estimate has been compared with other methods only for grips of 0.5 to 4 bolt diameters.

How the external load is shared

The joint constant is C = kb / (kb + km). Of an external load P, the bolt takes C P and the members give up the rest as lost clamp: the bolt load is Fb = Fi + C P and the clamp load left in the members is Fm = Fi − (1 − C) P, where Fi is the preload.

When the joint separates

Once the external load reaches P0 = Fi / (1 − C), the clamp load is gone and the members carry nothing. Above that the bolt carries all of P, and the tool says the joint has opened. The factor against separation is n0 = P0 / P.

Safety factors

The proof load is the proof strength times the tensile stress area. The load factor is the external load that brings the bolt to proof, divided by P. That load is (Sp At − Fi) / C when the separation load is at or above the proof load, and Sp At itself when the joint opens first. The factor on proof load is np = Sp At / Fb, how far the present bolt load is below proof. The load factor is how many times the external load can grow before the bolt reaches proof. The factor on proof load is how far the present bolt load is below proof.

Worked example: an M10x1.5 bolt of class 10.9, steel members, E 207 GPa (an example value, not yours), grip 30 mm with 20 mm of shank and 10 mm of thread, preload 75% of proof, external load 10 kN. Then At = 57.99 mm², kb = 484 700 N/mm, km = 1 936 000 N/mm and C = 0.200. The proof load is 48.13 kN and the preload 36.10 kN. The bolt load is 38.10 kN (657 MPa) and 28.10 kN of clamp is left. The joint separates at 45.14 kN, n0 = 4.51, and since that is below the proof load the load factor is 48.13 / 10 = 4.81: the joint opens first, at 4.51 times this load. The factor on proof load is 1.26.

Limits

A first estimate for one bolt and nut through metal parts of one material, loaded in pure tension along the bolt axis at the head and nut faces. Member stiffness is an estimate, and the real preload is uncertain by a wide margin whatever the torque wrench says, so treat the factors as rough. It leaves out shear and slip, bending and prying, loads applied inside the joint, gaskets, tapped holes, fatigue, temperature and the loss of preload over time. A joint whose failure could hurt someone is designed and checked by a qualified engineer.

The spring model of a preloaded joint and the 30° pressure-cone estimate of member stiffness, as set out by Open Exam Prep, UWA's DANotes and Machine Design.

Rapid Datum makes the drawing from your STEP file. First drawing free.

Related tools: the bolt torque calculator gives the torque for a preload, the thread engagement calculator checks the thread strips last, the fastener hole lookup gives the holes, the fixed and floating fastener calculator places them, and the fatigue safety factor calculator takes the load cycle on from here.

Questions

What is the joint constant C?

The share of an external load the bolt carries, kb / (kb + km). The members, being much stiffer than the bolt, usually carry most of it.

What happens when the joint separates?

The members stop carrying any clamp load and the bolt carries the whole external load, so the bolt load rises faster from there.

Why are there two load factors?

One says how many times the external load can grow before the bolt reaches proof. The other says how far the bolt load, as it is now, sits below proof.