Toolbox

Fixed and floating fastener calculator

When two parts are held together by screws, bolts or pins, the position tolerance on their holes decides whether every pair of parts will go together. Enter the fastener and the clearance hole, and the calculator gives the largest position tolerance each part can have and still assemble at the worst case, or the clearance hole for a tolerance you have already chosen.

The formulas are the ones in ASME Y14.5, Nonmandatory Appendix B, Formulas for Positional Tolerancing. F is the fastener at its largest (its MMC), H is the clearance hole at its smallest (its MMC), and T is the position tolerance diameter at MMC.

More calculators in the Toolbox

Floating fastener: both parts have clearance holes

H = F + T, so T = H − F, and the same T applies to both parts.

A bolt passes through clearance holes in both parts and is held by a nut. At the worst case each hole is at its smallest and sits at the edge of its position zone, off by T/2, the two holes off in opposite directions. The bolt at its largest just touches both.

Floating fastener at the worst case: two plates with clearance holes shifted opposite ways, the bolt at its largest touching both
Not to scale: the clearance is drawn wide so it can be seen.

Worked example: an M6 screw through two plates with Ø6.6 clearance holes. T = 6.6 − 6 = 0.6, so each plate gets position Ø0.6 at MMC. With four holes and datums A, B and C:

In inches, a 1/4 screw through normal Ø.281 clearance holes: T = .281 − .250 = .031, so position Ø.031 at MMC on each plate.

Fixed fastener: one part is threaded or pressed

H = F + T1 + T2, where T1 is the clearance hole's position tolerance and T2 the threaded or press-fit hole's, with a projected tolerance zone on the threaded hole.

A screw passes through a clearance hole in one part and threads into the other, so the threaded hole fixes the screw. There is one clearance gap between the two parts, not two, so the total H − F is shared between them.

Fixed fastener at the worst case: a cover with a clearance hole and a threaded base, each off its true position, the screw at its largest touching the clearance hole
Not to scale: the clearance is drawn wide so it can be seen.

Worked example: an M6 screw through a Ø6.6 clearance hole into an M6x1 tapped hole, the cover 6 thick. T1 + T2 = 6.6 − 6 = 0.6. Split equally, each part gets Ø0.3 at MMC, with a projected zone of 6 on the tapped hole. With four holes and datums A, B and C:

Splitting the tolerance between the two parts

In the fixed case T1 + T2 is fixed, and you choose how to share it. The calculator starts at an equal split and the slider moves tolerance from one part to the other while the sum holds. Give more to the part that is harder to make to position: a cast or welded part may need more than a machined one.

Projected tolerance zone

A screw does not stay inside its threaded hole: it carries on through the mating part, so any tilt of the thread is magnified over that height. A projected tolerance zone (Ⓟ in the frame, followed by its height) moves the position zone up out of the threaded hole to where the screw passes through the mating part. Its height P is the mating part's largest thickness.

Without a projected zone, the threaded hole's tolerance must also cover that tilt: H = F + T1 + T2 × (1 + 2P/D), where D is the smallest depth of thread engagement. With an equal split, T = (H − F) / (2 + 2P/D). In the example with P = 6 and D = 9, 1 + 2P/D = 2.333, so each part gets Ø0.18 instead of Ø0.3. That loss is why the projected zone is the better callout, and why the calculator shows both results when you turn it off.

What the formula does not cover

The result guarantees assembly at the worst case: fastener at its largest, holes at their smallest, and both parts' holes located from datum features that mate in assembly. As a hole departs from its smallest size, the MMC modifier gives it extra tolerance. The formula does not cover datum feature shift, counterbore and head seating, or a fastener that is not perpendicular unless the projected zone is used. It does not handle slots, keys, or patterns with unequal counts.

Questions

What is the difference between a fixed and a floating fastener?

A floating fastener passes through clearance holes in both parts and is held by a nut, so both holes can float around it. A fixed fastener is held by one of the parts, in a threaded or press-fit hole, so only the clearance hole in the other part has room to move.

What is the floating fastener formula?

T = H − F: the position tolerance at MMC for each part is the smallest clearance hole minus the largest fastener. For an M6 screw in Ø6.6 holes that is Ø0.6.

What is the fixed fastener formula?

T1 + T2 = H − F, with a projected tolerance zone on the threaded hole. Split equally, an M6 screw in a Ø6.6 clearance hole gives Ø0.3 at MMC on each part.

Why use a projected tolerance zone on a tapped hole?

Because the screw carries the thread's tilt up through the mating part. Without a projected zone the formula becomes H = F + T1 + T2 × (1 + 2P/D), which leaves much less tolerance: Ø0.18 instead of Ø0.3 in the M6 example.

Does the calculator save my inputs?

No. Copy link puts the inputs in the address after the #, so the link reopens them. Nothing is stored on our server, and no account or email is needed.