Bolt torque and preload calculator
You need a tightening torque for a screw, or you want to know what clamp load a given torque produces. The honest answer is a relation with one very uncertain number in it, the nut factor, and this tool gives the torque while keeping that uncertainty in view. It loads with a worked example filled in. Replace every value marked as an example with your own.
More calculators in the Toolbox
Torque, preload and the nut factor
T = K × F × d. T is the tightening torque, F the preload (the clamp load the screw puts on the joint), d the nominal thread diameter, and K the nut factor. Use d in metres for N·m and in inches for lbf·in; lbf·ft is lbf·in divided by 12. Proof load here is proof strength times the tensile stress area. The tensile stress area of a metric thread is (π/4)(d − 0.9382p)² and of a unified inch thread 0.7854(d − 0.9743/n)², where p is the pitch and n the threads per inch.
Worked example: an M10x1.5 screw of property class 10.9 (ISO 898-1:2013), tightened to 75% of proof load with K 0.20. The stress area is 57.99 mm². The proof strength is 830 MPa, so the proof load is 830 × 57.99 = 48.1 kN and the preload is 36.1 kN. The torque is 0.20 × 36 100 N × 0.010 m = 72.2 N·m. With K 0.15 the same preload needs 54.1 N·m. If K were 25% lower or higher than you entered, the same 72.2 N·m gives 48.1 kN (100% of proof load) at K 0.15 and 28.9 kN (60%) at K 0.25. At the low end this torque reaches the screw's proof load.
Choosing a nut factor
K is the least certain number in this calculation. Where it matters, measure it on your own parts. Dry plain steel is 0.20, the one value three pages agree on (Fastenal, NSS Fasteners, the NASA fastener design manual). Lubricated is 0.15 (Fastenal), down to 0.10 when well lubricated (NSS). As listed by NSS: zinc plated 0.20 or more; cadmium plated 0.18 to 0.19; black oxide, lightly oiled 0.15 to 0.17; moly paste, white lead or wax 0.10 to 0.14. As listed by Fastenal: Teflon/Xylan coatings about 0.12 or lower. As listed by industrialmonitordirect: anti-seize 0.12 to 0.15, depending on brand; use the anti-seize maker's figure. The tool has no default for K.
How much preload: proof load and percent of proof
Supplier torque tables we read use 75% of proof load. Your joint may need more or less, and its designer decides. Some tables use a percentage of yield strength instead. Yield is higher than proof strength, so 75% of yield is a higher preload than 75% of proof load. Check which one a table uses before you compare torques. The tool offers a proof strength for property classes 8.8 (580 MPa up to M16, 600 MPa over M16), 10.9 and 12.9 from ISO 898-1:2013, Table 3 as published and cross-checked by our reviewer (we did not read the standard itself), and for SAE grade 5 from 1/4 to 1 in and SAE grade 8 from 1/4 to 1-1/2 in as quoted by Mutual Screw from SAE J429 (we did not read the standard itself), one value at a time with its source named, and otherwise you type it. Over 90% of proof load leaves little margin for the scatter in K; the tool warns at 90% and again at 100%, and never refuses.
Why the same torque gives different clamp loads
At a fixed torque the preload goes as 1/K. A nut factor 25% low gives 133% of the preload and one 25% high gives 80%. Most of the torque goes into friction under the head and in the threads, and how much depends on lubricant, plating, surface finish, tightening speed and reuse. That is why the tool always shows the spread beside the answer, as a force and as a percentage of proof load.
Putting a torque on a drawing
A tightening torque belongs on the assembly drawing or the assembly instruction, not on the part drawing of the screw or of a part with a tapped hole, because it controls an assembly operation. A torque note needs a tolerance and the thread condition, in the verb-first form TIGHTEN M10x1.5 SCREWS TO 72 ±7 N·m, THREADS DRY. The size is written as the thread callout builder writes it, without the class. For the screw's holes see the fastener hole tool, and for how deep the thread must go the thread engagement calculator.
A first estimate of tightening torque from the short torque relation, T = K·F·d. The answer is only as good as the nut factor you entered. The nut factor isn't a material property: it changes with lubricant, plating, surface finish, tightening speed and reuse, and a wrong guess moves the clamp load by tens of percent. For a joint whose failure could hurt someone or cost real money, take the torque from the fastener maker or the governing standard, or measure the bolt tension directly. This tool doesn't check the joint: not the clamped parts, the thread engagement, the external load or fatigue.
Rapid Datum makes the drawing from your STEP file, thread callouts included. First drawing free.
Questions
How do you calculate bolt tightening torque?
T = K × F × d: the nut factor times the preload times the nominal diameter. An M10 screw at 36.1 kN preload with K 0.20 needs 72.2 N·m.
What is the nut factor K?
The number that turns torque into clamp load. Dry plain steel is about 0.20, lubricated threads lower. It changes with lubricant, plating and reuse, so a wrong guess moves the clamp load by tens of percent.
What percentage of proof load should a bolt be tightened to?
The supplier torque tables we read use 75% of proof load. Your joint may need more or less, and its designer decides.