Toolbox

Inch to mm tolerance converter

You have a toleranced dimension in inches and need it in millimetres, or the reverse, for a second-unit drawing, a supplier or an inspection report. A plain converter gives too many digits, and rounding them the usual way can put the new limits outside the old ones. This tool chooses the number of decimal places from the tolerance and rounds so that cannot happen. Use the converted values the way you would any other: put the original on the drawing and give the converted ones as reference.

More calculators in the Toolbox

Why a plain conversion can fail good parts

Take 1.387 ±.003 in. The limits are 1.384 and 1.390 in, which are 35.1536 and 35.3060 mm. Convert the nominal and the tolerance separately and you get 35.23 ±0.08 mm, which reaches 35.31 mm. That is outside the original upper limit of 35.3060, so a part that passes the converted drawing can fail the original. The tool checks the rounded plus and minus form against the original limits, and when it fails it gives the limits instead: 35.16-35.30.

How many decimal places to keep

The places come from the total tolerance in the original unit. This is Rapid Datum's method table, the rounding method Rapid Datum uses on dual-unit drawings.

Inch to mm: total tolerance (in)mm placesmm to inch: total tolerance (mm)inch places
0.4 and over02.0 and over2
0.04 up to 0.410.2 up to 2.03
0.004 up to 0.0420.02 up to 0.24
0.0004 up to 0.00430.002 up to 0.025
0.00004 up to 0.00044under 0.0026
under 0.000045

One inch is 25.4 mm exactly, the arithmetic here is exact decimal arithmetic, and rounding is half to even. For a size with a tolerance, the nominal and each tolerance are rounded to the places, and the new limits are checked against the original. If they stay inside, the answer is the plus and minus form: .250 ±.010 in is 6.35 ±0.25 mm, reaching 6.60 and 6.10 against the original 6.604 and 6.096. If they do not, the answer is the limits. A size with only one side, such as 50 +0.1/0 mm, is always converted as limits, so no nil side is written.

Converting limits and fits

Limits are converted exactly, then the upper limit is rounded down and the lower limit up, so the new limits can never accept a part the old ones reject. The limits .874 to .877 in are 22.200-22.275 mm, and 25.000 to 25.021 mm is .9843-.9850 in. The lower limit comes first and a hyphen joins them, as Rapid Datum prints a limit-form size. If a very narrow band closes up under this rounding, a place is added until it does not.

For a dual-dimension drawing the tool also writes the primary value with the converted one in brackets, as Rapid Datum prints it: 1.387 ±.003 [35.16-35.30]. The bracket is capped at 4 places in inches and 3 in mm. The note that goes with it reads DIMENSIONS IN [ ] ARE MILLIMETERS. or INCHES. Angles, threads, surface texture and datum letters are not converted, as the drawing engine does not convert them either; see the surface finish converter for roughness. An ISO fit class is not converted to an inch class or the reverse: ISO 286 and ASME B4.1 limits are not conversions of each other. For the limits of an ISO fit, use the ISO 286 fit calculator.

Converting basic dimensions

A basic dimension is exact, so it is converted to more places and rounded half to even: inches to millimetres at 3 places and millimetres to inches at 5. Basic 1.5 in is 38.1 mm and basic 30 mm is 1.18110 in. In the bracket, a millimetre value is capped at 3 places and an inch value at 4. A tolerance on its own, such as the zone in a feature control frame, is converted to one place more than the table gives for it, capped at 4 places in inches and 3 in mm, rounded toward zero, so the converted zone is never larger than the original: Ø0.25 mm is Ø.0098 in.

Soft conversion and when not to convert

Converting a drawing to the other unit without redesigning the part is called soft conversion. It gives reference values for suppliers and inspectors who measure in the other unit. The original drawing stays the authority. A part that will be made to the other unit is better redesigned in it (hard conversion), so its sizes are round numbers in that unit.

For the general tolerance of a size, use the ISO 2768 lookup, and the tolerance stack-up calculator adds up a chain of dimensions. The guide to reading a print shows where these values sit on a drawing.

Rapid Datum makes the drawing from your STEP file in inches, millimetres or both. First drawing free.

Questions

How do you convert a tolerance from inches to mm?

Convert the nominal and the tolerance, round them to the places the total tolerance sets, and check that the new limits are inside the original ones. If they are not, convert the limits instead, rounding the upper limit down and the lower limit up.

How many decimal places should I keep when converting a tolerance?

It depends on the total tolerance. For inches to millimetres, a total of .004 to .04 in keeps 2 places, and a total of .0004 to .004 in keeps 3. The page's table gives every step in both directions.

Why not just multiply by 25.4?

The product has more digits than the tolerance can justify, and rounding the nominal and tolerance separately can put a limit outside the original, so a good part can be rejected or a bad one accepted. Rounding the limits inward avoids that.