Toolbox › Fastener hole tool

M8x1: tap drill and clearance hole sizes, with drawing callouts

Every number for a M8x1 hole, each beside the standard it comes from, and the note to put on the drawing. Change the fit, the depth or the percent of thread and the callouts follow.

More calculators in the Toolbox

The values for M8x1

ValueM8x1Source
Tap drill7.0 mm, about 77% of threadISO 2306:1972, drills for use prior to tapping screw threads (read)
Minor diameter limits6.917 to 7.153 mm, 6HISO 965-1 class 6H minor diameter limits, as printed in ISO 2306:1972 (read)
Clearance hole, fine (H12)Ø8.4 +0.15/0 mmISO 273, as reproduced by AmesWeb (ISO 273 not read); the H12, H13 and H14 limits per ISO 286-2
Clearance hole, medium (H13)Ø9 +0.22/0 mmISO 273, as reproduced by AmesWeb (ISO 273 not read); the H12, H13 and H14 limits per ISO 286-2
Clearance hole, coarse (H14)Ø10 +0.36/0 mmISO 273, as reproduced by AmesWeb (ISO 273 not read); the H12, H13 and H14 limits per ISO 286-2
Socket head height H8 mmISO 4762, as reproduced by Engineers Edge
Counterbore diameterNot shown yet: DIN 974-1 has not been read.
Countersink, 90°Ø17.30 to 17.55 mm, depth t 4.28 mmISO 15065:2005, Table 1 (read)
Tensile stress area39.17 mm² (tensile area only)ISO 898-1 form

The callouts at the defaults

Tapped blind hole (thread 2 × D deep)

Ø7 ↧19
M8x1-6H ↧16 MIN FULL THREAD

Tapped through hole

M8x1-6H THRU

Clearance hole, medium

Ø9 +0.22/0 THRU

Countersunk hole, flat head

Ø9 +0.22/0 THRU
⌵Ø17.30-17.55 X 90°

How the numbers are worked out

Assumptions and limits

Common questions

What size drill for a M8x1 tap?

7 mm, per ISO 2306:1972. It gives about 77% of thread and falls inside the thread's minor diameter limits (6.917 to 7.153 mm, 6H).

What is the clearance hole for a M8x1 screw?

Ø9 +0.22/0, the medium (ISO 273, H13) fit. Close and loose fits are in the tool above.

How do I call out a tapped hole on a drawing?

Blind: Ø7 ↧19 / M8x1-6H ↧16 MIN FULL THREAD. The tap drill and its depth come first, then the thread and its full-thread depth, each on its own line. Tapped through: M8x1-6H THRU, one line.

Why is there no torque value?

Because the torque for a preload depends on the nut factor K of your parts, which only torque-tension testing gives (ISO 16047). Enter your K and the tool works T = K × D × F; it never assumes one.