The values for 4-40 UNC

Value4-40 UNCSource
Tap drill#43 (.0890 in), about 71% of threadOSG tap drill chart, 2024 (75% column); stock drill the nearest standard number, letter or fraction size
Minor diameter limits.0849 to .0939 in, 2BASME B1.1 class 2B minor diameter limits, as printed by OSG (B1.1 not read)
Clearance hole, closeØ.120 inASME B18.2.8, as reproduced by MechaniCalc (B18.2.8 not read)
Clearance hole, normalØ.128 inASME B18.2.8, as reproduced by MechaniCalc (B18.2.8 not read)
Clearance hole, looseØ.144 inASME B18.2.8, as reproduced by MechaniCalc (B18.2.8 not read)
Socket head height H.1120 inASME B18.3, as reproduced by Engineers Edge
Counterbore diameter.219 in (7/32)ASME B18.3 appendix, as reproduced by Engineers Edge
CountersinkNot shown yet: the inch 82° head standards have not been read.
Tensile stress area0.00603 in² (tensile area only)ASME B1.1 form

The callouts at the defaults

Tapped blind hole (thread 2 × D deep)

Ø.089 ↧.34
4-40 UNC-2B ↧.25 MIN FULL THREAD

Tapped through hole

4-40 UNC-2B THRU

Clearance hole, normal

Ø.128 THRU

Counterbored hole, socket head cap screw

Ø.128 THRU
⌴Ø.219 ↧.14

How the numbers are worked out

Assumptions and limits

Common questions

What size drill for a 4-40 UNC tap?

#43 (.0890 in), per a 75% thread. It gives about 71% of thread and falls inside the thread's minor diameter limits (.0849 to .0939 in, 2B).

What is the clearance hole for a 4-40 UNC screw?

Ø.128, the normal (ASME B18.2.8) fit. Close and loose fits are in the tool above.

How do I call out a tapped hole on a drawing?

Blind: Ø.089 ↧.34 / 4-40 UNC-2B ↧.25 MIN FULL THREAD. The tap drill and its depth come first, then the thread and its full-thread depth, each on its own line. Tapped through: 4-40 UNC-2B THRU, one line.

Why is there no torque value?

Because the torque for a preload depends on the nut factor K of your parts, which only torque-tension testing gives (ISO 16047). Enter your K and the tool works T = K × D × F; it never assumes one.