Column buckling calculator
You are sizing a strut, push rod, leg, lead screw or actuator rod in compression and need the load at which it buckles, and which formula applies to its length. The tool loads with a worked example filled in. Replace every value marked as an example with your own.
More calculators in the Toolbox
Euler's formula for long columns
Pcr = C π² E I / l². Pcr is the critical load, C the end-condition constant, E Young's modulus, I the smaller second moment of area of the section and l the length between supports. It applies when the slenderness ratio l / k is above the changeover (l/k)₁ = √(2 π² C E / Sy), where k = √(I / A) is the radius of gyration and Sy the compressive yield strength.
The Johnson formula for shorter columns
At or below the changeover the parabolic (J. B. Johnson) formula applies: Pcr = A × [ Sy − (Sy × (l/k) / (2π))² / (C E) ]. At the changeover both formulas give A × Sy / 2. The squash load A × Sy is shown beside the Johnson value; when the critical load is at least 95% of it, compressive yield governs, not buckling.
Worked example: a round bar Ø20, 600 long, pinned at both ends, E 200 GPa and Sy 250 MPa (example values). k = 5.00 mm, so l / k = 120.0. The changeover is 125.7, so the Johnson formula applies and Pcr = 42.7 kN. The same bar fixed at one end and free at the other (C = 1/4) has its changeover at 62.8, so Euler's formula applies: 10.8 kN.
End conditions
| Ends | C | K = 1/√C |
|---|---|---|
| Fixed-free | 1/4 | 2 |
| Pinned-pinned | 1 | 1 |
| Fixed-pinned | 2 (theory gives 2.05; rounded down) | 0.71 |
| Fixed-fixed | 4 | 0.5 |
The effective length is K·l. Real ends are never perfectly fixed. Many designers use a lower end-condition constant than the theoretical one for fixed ends; use the value your design practice calls for. Fixed-fixed is the case to watch: C = 4 assumes ends that can't rotate at all.
Slenderness ratio
The slenderness ratio l / k uses the least radius of gyration of the section, because a column buckles about its weakest axis. For an angle that is kv, about the minor principal axis, not either leg: a strut taken about a leg would be credited with far too high a buckling load. Typing A and I, enter the smaller second moment of area of the section. For an angle, that is about its minor principal axis.
Why a column needs a generous safety factor
The buckling load of a straight, centrally loaded column of uniform section, with the ends you picked. Real columns are never perfectly straight or perfectly loaded, and a column fails suddenly and without warning, so the working load must be well below this value. The tool leaves out eccentric and side loads, local buckling of thin walls, twisting, and the rules of any structural code. A column that supports people or a load overhead is designed and checked by a qualified engineer. How large a factor a column needs depends on how straight it is, how the load is applied and the practice or code you design to.
Euler's column formula and the parabolic (J. B. Johnson) formula, in the form given in machine design textbooks such as Shigley's Mechanical Engineering Design.
Questions
When do I use Euler and when Johnson?
Euler above the changeover slenderness √(2 π² C E / Sy), Johnson at or below it. The tool picks and says why.
Does the calculator save my inputs?
No. Copy link puts the inputs in the address after the #, so the link reopens them. Nothing is stored on our server, and no account or email is needed.